Shown here are the results of a BLAST search against the genome using the input sequence. The pipeline uses this
to extract flanking regions for cloning. If the result of the multiple sequence alignment is
not as expected, these results could be used for further investigation.
qseqid
sseqid
percentage.identical
alignment.length
no.mismatch
no.gap.openings
qstart
qend
sstart
send
evalue
bitscore
0
TraesCS3B01G597100
chr3B
100.000
2906
0
0
1
2906
819703491
819706396
0.000000e+00
5367.0
1
TraesCS3B01G597100
chr3B
98.233
1811
24
4
437
2247
812489102
812487300
0.000000e+00
3160.0
2
TraesCS3B01G597100
chr3B
90.864
602
43
5
1647
2247
812486973
812486383
0.000000e+00
797.0
3
TraesCS3B01G597100
chr3B
94.118
153
7
1
84
236
812489331
812489181
6.260000e-57
231.0
4
TraesCS3B01G597100
chr3B
84.874
119
14
2
100
218
25328230
25328344
1.830000e-22
117.0
5
TraesCS3B01G597100
chr3D
91.927
1796
102
10
411
2180
604748461
604750239
0.000000e+00
2473.0
6
TraesCS3B01G597100
chr3D
88.280
1715
152
18
504
2180
604702911
604701208
0.000000e+00
2008.0
7
TraesCS3B01G597100
chr3D
92.737
358
26
0
2239
2596
345760124
345759767
4.290000e-143
518.0
8
TraesCS3B01G597100
chr3D
77.637
237
44
9
2614
2845
118421795
118422027
5.050000e-28
135.0
9
TraesCS3B01G597100
chr3D
95.652
46
1
1
2202
2247
604750241
604750285
4.020000e-09
73.1
10
TraesCS3B01G597100
chr3D
93.478
46
2
1
2202
2247
604701206
604701162
1.870000e-07
67.6
11
TraesCS3B01G597100
chr3A
90.794
1347
65
21
222
1526
735419599
735418270
0.000000e+00
1746.0
12
TraesCS3B01G597100
chr3A
92.233
412
23
3
1773
2180
735410574
735410168
2.510000e-160
575.0
13
TraesCS3B01G597100
chr3A
91.923
260
17
1
1523
1778
735412006
735411747
7.660000e-96
361.0
14
TraesCS3B01G597100
chr3A
87.375
301
29
4
972
1263
735257250
735256950
1.290000e-88
337.0
15
TraesCS3B01G597100
chr3A
88.554
166
8
3
1
156
735430011
735429847
1.060000e-44
191.0
16
TraesCS3B01G597100
chr3A
82.199
191
27
3
617
800
698032284
698032094
1.080000e-34
158.0
17
TraesCS3B01G597100
chr3A
84.337
166
19
4
624
784
698146379
698146216
3.880000e-34
156.0
18
TraesCS3B01G597100
chrUn
86.621
1450
163
18
565
2001
374475320
374476751
0.000000e+00
1574.0
19
TraesCS3B01G597100
chrUn
92.737
358
26
0
2239
2596
80157757
80158114
4.290000e-143
518.0
20
TraesCS3B01G597100
chrUn
92.437
238
17
1
2003
2240
430919059
430918823
3.590000e-89
339.0
21
TraesCS3B01G597100
chrUn
86.486
111
4
2
1
100
374475159
374475269
8.510000e-21
111.0
22
TraesCS3B01G597100
chrUn
92.537
67
3
2
2587
2653
229102108
229102172
8.570000e-16
95.3
23
TraesCS3B01G597100
chr7D
95.556
360
16
0
2237
2596
15213722
15214081
6.980000e-161
577.0
24
TraesCS3B01G597100
chr7D
91.899
358
29
0
2239
2596
52485283
52485640
4.320000e-138
501.0
25
TraesCS3B01G597100
chr7D
95.865
266
10
1
2642
2906
15215531
15215796
2.070000e-116
429.0
26
TraesCS3B01G597100
chr7D
89.179
268
25
3
2642
2906
15215442
15215708
6.000000e-87
331.0
27
TraesCS3B01G597100
chr7D
80.422
332
40
13
2595
2903
15215287
15215616
2.250000e-56
230.0
28
TraesCS3B01G597100
chr2A
95.304
362
13
1
2239
2596
708518796
708519157
3.250000e-159
571.0
29
TraesCS3B01G597100
chr2A
94.361
266
14
1
2642
2906
708520504
708520769
9.700000e-110
407.0
30
TraesCS3B01G597100
chr5D
92.737
358
26
0
2239
2596
444783228
444783585
4.290000e-143
518.0
31
TraesCS3B01G597100
chr5D
78.166
458
88
7
570
1021
37138816
37139267
6.130000e-72
281.0
32
TraesCS3B01G597100
chr5B
92.737
358
26
0
2239
2596
534893110
534892753
4.290000e-143
518.0
33
TraesCS3B01G597100
chr7A
92.179
358
28
0
2239
2596
90525440
90525083
9.290000e-140
507.0
34
TraesCS3B01G597100
chr7A
83.575
207
27
5
2599
2803
40531345
40531144
1.370000e-43
187.0
35
TraesCS3B01G597100
chr7A
81.215
181
25
6
97
277
330101533
330101704
1.400000e-28
137.0
36
TraesCS3B01G597100
chr4A
91.643
359
30
0
2238
2596
673284079
673284437
5.590000e-137
497.0
37
TraesCS3B01G597100
chr4A
89.130
92
4
2
390
481
738541801
738541716
3.060000e-20
110.0
38
TraesCS3B01G597100
chr4A
89.130
92
4
2
390
481
738545715
738545630
3.060000e-20
110.0
39
TraesCS3B01G597100
chr4B
83.594
256
30
10
2614
2864
658660684
658660932
2.250000e-56
230.0
40
TraesCS3B01G597100
chr4B
89.231
130
14
0
604
733
49745894
49745765
2.320000e-36
163.0
41
TraesCS3B01G597100
chr4B
81.106
217
26
15
2639
2848
667926809
667926601
3.000000e-35
159.0
42
TraesCS3B01G597100
chr6D
79.913
229
26
17
2580
2803
456949234
456949447
1.800000e-32
150.0
43
TraesCS3B01G597100
chr7B
90.698
43
4
0
100
142
745303123
745303165
1.120000e-04
58.4
These results show the homologous regions that are presented in the multiple sequence alignment. HSPs from the
BLAST search that are within 2000 bases of each other have been grouped together. Homologous regions that are
purely upstream or downstream may be removed if they don't overlap both primers.
query
scaffold
start
end
length
rev.comp
avg.bitscore
max.bitscore
avg.percent.identical
query.start
query.end
num_hsp
groupid
homo_length
0
TraesCS3B01G597100
chr3B
819703491
819706396
2905
False
5367.00
5367
100.0000
1
2906
1
chr3B.!!$F2
2905
1
TraesCS3B01G597100
chr3B
812486383
812489331
2948
True
1396.00
3160
94.4050
84
2247
3
chr3B.!!$R1
2163
2
TraesCS3B01G597100
chr3D
604748461
604750285
1824
False
1273.05
2473
93.7895
411
2247
2
chr3D.!!$F2
1836
3
TraesCS3B01G597100
chr3D
604701162
604702911
1749
True
1037.80
2008
90.8790
504
2247
2
chr3D.!!$R2
1743
4
TraesCS3B01G597100
chr3A
735418270
735419599
1329
True
1746.00
1746
90.7940
222
1526
1
chr3A.!!$R4
1304
5
TraesCS3B01G597100
chr3A
735410168
735412006
1838
True
468.00
575
92.0780
1523
2180
2
chr3A.!!$R6
657
6
TraesCS3B01G597100
chrUn
374475159
374476751
1592
False
842.50
1574
86.5535
1
2001
2
chrUn.!!$F3
2000
7
TraesCS3B01G597100
chr7D
15213722
15215796
2074
False
391.75
577
90.2555
2237
2906
4
chr7D.!!$F2
669
8
TraesCS3B01G597100
chr2A
708518796
708520769
1973
False
489.00
571
94.8325
2239
2906
2
chr2A.!!$F1
667
AutoCloner calculated primer pairs
These primer pairs were selected by Autocloner to minimize primer penalty (calculated by Primer3),
whilst remaining within the specified product range where possible.
Listed here are all possible primers based on the multiple sequence alignment and SNPs generated
previously. A lower penalty score indicates a better primer. If the AutoCloner primers did not work
during PCR or sequencing,
these could be used as alternatives.